1.
Curr Probl Cardiol ; 49(5): 102467, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38369208

RESUMO

BACKGROUND: Atrial fibrillation is the most common sustained cardiac arrhythmia in adults and it is associated with a high burden of mortality and morbidity worldwide. Catheter ablation is increasingly used to improve symptoms and prognosis in selected patients. Lower limb venous access with subsequent transseptal approach to the left atrium is the standard procedure for atrial fibrillation catheter ablation. CASE PRESENTATION: We report an unusual case of complex venous anomaly with a left-sided inferior vena cava with hemiazygos continuation to a persistent left superior vena cava draining in an enlarged coronary sinus in a patient with persistent atrial fibrillation scheduled for transcatheter ablation. DISCUSSION: Lower limb venous anomalies may limit a standard transseptal approach to the left atrium thus precluding an effective catheter ablation procedure for atrial fibrillation. Alternative interventions, such as unconventional percutaneous access, thoracoscopic approach and "ablate and pace" procedures, may be necessary in patients with symptomatic atrial fibrillation and complex venous anomalies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Isomerismo , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia , Veia Cava Superior/anormalidades
2.
Curr Probl Cardiol ; 48(11): 101920, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37392981

RESUMO

Incidental epicardial adipose tissue (EAT) and subepicardial fat infiltration on CT scans are not uncommon and the differential diagnosis can be a challenge. Considering the vastness of the possible disorders, it is important to differentiate physiologic age-related condition from pathologic disease. We present a case of an asymptomatic 81-year-old woman in which according to ECG and CMR findings we considered as possible differential diagnoses arrhythmogenic cardiomyopathy (ACM) dominant-right variant, lipomatosis and physiological growth of epicardial fat. We focus on patient characteristics, location of the fat replacement, heart morphovolumetry, wall motion of the ventricles and absence of late gadolinium enhancement to diagnose pericardial fat hypertrophy and physiological fatty infiltration. The role of EAT is unclear and it could play a part in the development of atherosclerosis and atrial fibrillation. Therefore, the clinicians should not underestimate this condition even if it would be an incidental finding in asymptomatic patients.


Assuntos
Displasia Arritmogênica Ventricular Direita , Fibrilação Atrial , Idoso de 80 Anos ou mais , Feminino , Humanos , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/patologia , Fibrilação Atrial/patologia , Meios de Contraste , Gadolínio , Miocárdio
3.
Front Cardiovasc Med ; 10: 1088697, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910536

RESUMO

Background: Phrenic nerve stimulation is a well-recognized complication related to cardiac implantable electronic devices, in particular with left ventricular coronary sinus pacing leads for cardiac resynchronization therapy. Case presentation: We report an unusual case of symptomatic phrenic nerve stimulation due to inadvertent placement of a right ventricular defibrillation lead in coronary sinus posterior branch in a patient with heart failure with reduced ejection fraction with a recently implanted single-chamber cardioverter defibrillator. Discussion: Phrenic nerve stimulation is a relatively common complication of left ventricular pacing. Inadvertent placement of a right ventricular lead in a coronary sinus branch is a rare but possible cause of phrenic nerve stimulation. Careful evaluation of intraprocedural fluoroscopic and electrocardiographic appearance of pacing and defibrillation leads during implantation may prevent inadvertent placement of a right ventricular lead in the coronary sinus.

4.
Eur Heart J Case Rep ; 7(2): ytad007, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36845832

RESUMO

Background: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults, and it is associated with a high burden of mortality and morbidity worldwide. AF can be managed with rate-control or rhythm-control strategies. The latter is increasingly used to improve symptoms and prognosis in selected patients, especially after the development of catheter ablation. Although this technique is generally considered safe, it is not free from rare but life-threatening procedure-related adverse events. Among these, coronary artery spasm (CAS) is an uncommon but potentially fatal complication that requires immediate diagnosis and treatment. Case summary: We report a case of severe multivessel CAS triggered by ganglionated plexi stimulation during pulmonary vein isolation with radiofrequency catheter ablation in a patient with persistent AF, promptly resolved after intracoronary nitrate administration. Discussion: Although rare, CAS is a serious complication of AF catheter ablation. Immediate invasive coronary angiography is key for both diagnosis confirmation and treatment of such dangerous condition. As the number of invasive procedures increases, it is important that both interventional and general cardiologists are aware of possible procedure-related adverse events.

5.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36709469

RESUMO

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Assuntos
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedância Elétrica , Estudos Retrospectivos , Fibrilação Ventricular , Desfibriladores Implantáveis
6.
Int J Mol Sci ; 24(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36675028

RESUMO

Endothelial dysfunction (ED) causes worse prognoses in heart failure (HF) patients treated with cardiac resynchronization therapy (CRTd). ED triggers the downregulation of microRNA-130 (miR-130a-5p), which targets endothelin-1 (ET-1). Thus, we evaluated ED and the response to CRTd by assessing miR-130a-5p and ET-1 serum levels. We designed a prospective multi-center study with a 1-year follow-up to evaluate ED, ET-1, and miR-130a-5p in CRTd patients with ED (ED-CRTd) vs. patients without ED (NED-CRTd). Clinical outcomes were CRTd response, HF hospitalization, cardiac death, and all-cause death. At 1-year follow-up, NED-CRTd (n = 541) vs. ED-CRTd (n = 326) patients showed better clinical statuses, lower serum values of B type natriuretic peptide (BNP: 266.25 ± 10.8 vs. 297.43 ± 16.22 pg/mL; p < 0.05) and ET-1 (4.57 ± 0.17 vs. 5.41 ± 0.24 pmol/L; p < 0.05), and higher values of miR-130a-5p (0.51 ± 0.029 vs. 0.41 ± 0.034 A.U; p < 0.05). Compared with NED-CRTd patients, ED-CRTd patients were less likely to be CRTd responders (189 (58%) vs. 380 (70.2%); p < 0.05) and had higher rates of HF hospitalization (115 (35.3%) vs. 154 (28.5%); p < 0.05) and cardiac deaths (30 (9.2%) vs. 21 (3.9%); p < 0.05). Higher miR-130a-5p levels (HR 1.490, CI 95% [1.014−2.188]) significantly predicted CRTd response; the presence of hypertension (HR 0.818, CI 95% [0.669−0.999]), and displaying higher levels of ET-1 (HR 0.859, CI 98% [0.839−0.979]), lymphocytes (HR 0.820, CI 95% [0.758−0.987]), LVEF (HR 0.876, CI 95% [0.760−0.992]), and ED (HR 0.751, CI 95% [0.624−0.905]) predicted CRTd non-response. Higher serum miR-130a-5p levels (HR 0.332, CI 95% [0.347−0.804]) and use of ARNI (HR 0.319, CI 95% [0.310−0.572]) predicted lower risk of HF hospitalization, whereas hypertension (HR 1.818, CI 95% [1.720−2.907]), higher BNP levels (HR 1.210, CI 95% [1.000−1.401]), and presence of ED (HR 1.905, CI 95% [1.238−2.241]) predicted a higher risk of HF hospitalization. Hence, serum miR-130a-5p could identify different stages of ED and independently predict CRTd response, therefore representing a novel prognostic HF biomarker.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Hipertensão , MicroRNAs , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , MicroRNAs/genética , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/terapia , Biomarcadores , Hipertensão/etiologia
7.
Pharmacol Res ; 182: 106303, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35697289

RESUMO

OBJECTIVES: We evaluated whether Angiotensin receptor/Neprilysin inhibitors (ARNI) reduce heart failure (HF) hospitalizations and deaths in cardiac resynchronization therapy with defibrillator (CRTd) non-responders patients at 12 months of follow-up, modulating microRNAs (miRs) implied in adverse cardiac remodeling. BACKGROUND: adverse cardiac remodeling characterized by left ventricle ejection fraction (LVEF) reduction, left ventricular end-systolic volume (LVESv) increase, and the 6-minute walking test (6MWT) reduction are relevant pathological mechanisms in CRTd non-responders and could be linked to changes in miRNAs (miRs), regulating cardiac fibrosis, apoptosis, and hypertrophy. METHODS: miRs levels and clinical outcomes (LVEF, cardiac deaths, and 6MWT) were evaluated at baseline and one year of follow-up in CRTd non-responders divided into ARNI-users and Non-ARNI users. RESULTS: At baseline, there were no differences in levels of inflammatory markers, miR-18, miR-145, and miR-181 (p > 0.05) between Non-ARNI users (n 106) and ARNI-users (n 312). At one year of follow-up, ARNI-users vs. Non-ARNI users showed lowest inflammatory markers (p < 0.01) and miR-181 levels (p < 0.01) and higher values of miR-18 (p < 0.01)and miR-145 (p < 0.01). At one year of follow-up, ARNI-users had a higher increase of LVEF (p < 0.01) and 6MWT (p < 0.01) along with a more significant reduction of LVESv (p < 0.01) compared to Non-ARNI users. Cox regression analysis evidenced that ARNI-based therapies increase the probability of anti-remodeling effects of CRTd. Based on symptomatic improvements, echocardiographic and functional classification improvements, 37 (34.9%) patients among ARNI-users became responders, while only twenty (6.4%) patients became responders among Non-ARNi-users. CONCLUSIONS: ARNI might influence epigenetic mechanisms modulating miRs implicated in the adverse cardiac remodeling responses to CRTd.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , MicroRNAs , Antagonistas de Receptores de Angiotensina/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Combinação de Medicamentos , Epigênese Genética , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/genética , Humanos , MicroRNAs/genética , MicroRNAs/uso terapêutico , Neprilisina/uso terapêutico , Receptores de Angiotensina/uso terapêutico , Volume Sistólico , Resultado do Tratamento , Remodelação Ventricular
8.
Metabolism ; 137: 155243, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35732222

RESUMO

BACKGROUND: In patients with type 2 diabetes mellitus (T2DM) the vaso-vagal syncope (VVS) recurrence could be due to the alteration of autonomic system function, evaluated by heart rate variability (HRV), and by 123I-metaiodobenzylguanidine (123I-mIBG) myocardial scintigraphy indexes: Heart to Mediastinum ratio (H/Mlate), and Washout rate (WR). The SGLT2-I could modulate/reduce autonomic dysfunction in T2DM patients with VVS. This effect could reduce the VVS recurrence in T2DM patients. METHODS: In a prospective multicenter study, after propensity score matching, we studied a population of 324 T2DM patients with VVS, divided into 161 SGLT2-I-users vs. 163 Non-SGLT2-I users. In these patients as SGLT2-I-users vs. Non-SGLT2-I users, we investigated the HRV and 123I-MIBG modifications and VVS recurrence at 12 months of follow-up. RESULTS: At follow-up end, the SGLT2-I-users vs. Non-SGLT2-I users had best glucose homeostasis and lower values of inflammatory markers, and resting heart rate (p < 0.05). The SGLT2-I-users vs. Non-SGLT2-I users evidenced the lowest low frequency/high frequency ratio (LF/HFr), a significant difference for all the indexes of autonomic dysfunction via ECG Holter analysis, and higher values of H/Mlate (p < 0.05). Finally, comparing SGLT2-I-users vs. Non-SGLT2-I users, we found a higher rate of VVS recurrence events, specifically of the vasodepressor VVS recurrence at 1-year follow-up (p < 0.05). We did not find a significant difference of mixed and cardio-inhibitory VVS recurrence events at 1 year of follow-up in the study cohorts (p > 0.05). At the Cox regression analysis H/Mlate (0.710, [0.481-0.985]), and SGLT2-I therapy (0.550, [0.324-0.934]) predicted all causes of syncope recurrence at 1 year of follow-up. CONCLUSIONS: Non-SGLT2-I users vs. SGLT2-I-users had alterations of the autonomic nervous system, with a higher rate of VVS recurrence at 1 year of follow-up. The indexes of cardiac denervation predicted the VVS recurrence, while the SGLT2-I reduced the risk of VVS recurrence. CLINICAL TRIAL REGISTRATION NUMBER: NCT03717207.


Assuntos
Diabetes Mellitus Tipo 2 , Cardiopatias , Inibidores do Transportador 2 de Sódio-Glicose , Síncope Vasovagal , Humanos , 3-Iodobenzilguanidina , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Estudos Prospectivos , Sistema Nervoso Autônomo , Frequência Cardíaca/fisiologia , Síncope
9.
Circulation ; 145(25): 1829-1838, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35369700

RESUMO

BACKGROUND: Optimal timing for catheter ablation of ventricular tachycardia is an important unresolved issue. There are no randomized trials evaluating the benefit of ablation after the first implantable cardioverter defibrillator (ICD) shock. METHODS: We conducted a 2-phase, prospective, multicenter, randomized clinical trial. Patients with ischemic or nonischemic dilated cardiomyopathy and primary or secondary prevention indication for ICD were enrolled in an initial observational phase until first appropriate shock (phase A). After reconsenting, patients were randomly assigned 1:1 in phase B to immediate ablation (within 2 months from shock delivery) or continuation of standard therapy. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. Amiodarone intake was not allowed except for documented atrial tachyarrhythmias. On July 23, 2021, phase B of the trial was interrupted as a result of the first interim analysis on the basis of the Bayesian adaptive design. RESULTS: Of the 517 patients enrolled in phase A, 154 (30%) had ventricular tachycardia, 56 (11%) received an appropriate shock over a median follow-up of 2.4 years (interquartile range, 1.4-4.4), and 47 of 56 (84%) agreed to participate in phase B. After 24.2 (8.5-24.4) months, the primary end point occurred in 1 of 23 (4%) patients in the ablation group and 10 of 24 (42%) patients in the control group (hazard ratio, 0.11 [95% CI, 0.01-0.85]; P=0.034). The results met the prespecified termination criterion of >99% Bayesian posterior probability of superiority of treatment over standard therapy. No deaths were observed in the ablation group versus 8 deaths (33%) in the control group (P=0.004); there was 1 worsening heart failure hospitalization in the ablation group (4%) versus 4 in the control group (17%; P=0.159). ICD shocks were less frequent in the ablation group (9%) than in the control group (42%; P=0.039). CONCLUSIONS: Ventricular tachycardia ablation after first appropriate shock was associated with a reduced risk of the combined death or worsening heart failure hospitalization end point, lower mortality, and fewer ICD shocks. These findings provide support for considering ventricular tachycardia ablation after the first ICD shock. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01547208.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Humanos , Prognóstico , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
10.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34709504

RESUMO

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Medição de Risco , Fatores de Risco , Resultado do Tratamento
11.
ESC Heart Fail ; 8(6): 5204-5212, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34514741

RESUMO

AIMS: There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation. METHODS AND RESULTS: We retrospectively analysed remote monitoring data from 1141 CRT defibrillators. Propensity score with inverse-probability weighting method was used to balance AF and sinus rhythm (SR) groups. Analysis endpoints included total mortality, appropriate defibrillation shocks, and CRT percentage. There were 229 patients (20.1%) in the AF group and 912 patients (79.9%) in the SR group. Compared with SR patients, AF patients were older (median age, 77 vs. 72 years, P < 0.001), more frequently male (82.5% vs. 75.5%, P = 0.02), and had higher heart rate (75.7 vs. 71.0 b.p.m., P < 0.001). Of the 229 AF patients, 162 (70.7%) received suboptimal CRT (<98%) and 67 (29.3%) had adequate CRT (≥98%). During a median follow-up of 24 months, total mortality did not differ between AF and SR groups (propensity-score-weighted hazard ratio, HR 1.32 [95% confidence interval, 0.82-2.15], P = 0.25). The risk of appropriate shocks was significantly higher in the AF group with <98% CRT than in the SR group (weighted-HR, 1.99 [1.21-3.26], P = 0.006) and was similar in the AF group with ≥98% CRT versus the SR group (1.29 [0.66-2.53], P = 0.45). During follow-up, sinus rhythm was recovered in 23 patients in the AF group (10%) after a median time of 106 (42-256) days. The rate of sinus rhythm recovery in the AF group was 4.5 (95% CI, 2.8-6.7) per 100 patient-years; the rate of permanent AF occurrence in the SR group was 2.5 (95% CI, 1.9-3.3) per 100 patient-years. CONCLUSIONS: Although mortality was similar across patient groups, patients with permanent AF and suboptimal CRT had twofold higher risk of appropriate shocks than SR patients or AF patients with CRT ≥ 98%.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
12.
Cardiovasc Diabetol ; 19(1): 202, 2020 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-33248462

RESUMO

OBJECTIVES: To evaluate the effects of cardiac resynchronization therapy (CRTd) in patients with type 2 diabetes mellitus (T2DM) optimized via automatic vs. echocardiography-guided approach. BACKGROUND: The suboptimal atrio-ventricular (AV) and inter-ventricular (VV) delays optimization reduces CRTd response. Therefore, we hypothesized that automatic CRTd optimization might improve clinical outcomes in T2DM patients. METHODS: We designed a prospective, multicenter study to recruit, from October 2016 to June 2019, 191 consecutive failing heart patients with T2DM, and candidate to receive a CRTd. Study outcomes were CRTd responders rate, hospitalizations for heart failure (HF) worsening, cardiac deaths and all cause of deaths in T2DM patients treated with CRTd and randomly optimized via automatic (n 93) vs. echocardiography-guided (n 98) approach at 12 months of follow-up. RESULTS: We had a significant difference in the rate of CRTd responders (68 (73.1%) vs. 58 (59.2%), p 0.038), and hospitalizations for HF worsening (12 (16.1%) vs. 22 (22.4%), p 0.030) in automatic vs. echocardiography-guided group of patients. At multivariate Cox regression analysis, the automatic guided approach (3.636 [1.271-10.399], CI 95%, p 0.016) and baseline highest values of atrium pressure (automatic SonR values, 2.863 [1.537-6.231], CI 95%, p 0.006) predicted rate of CRTd responders. In automatic group, we had significant difference in SonR values comparing the rate of CRTd responders vs. non responders (1.24 ± 0.72 g vs. 0.58 ± 0.46 g (follow-up), p 0.001), the rate of hospitalizations for HF worsening events (0.48 ± 0.29 g vs. 1.18 ± 0.43 g, p 0.001), and the rate of cardiac deaths ( 1.13 ± 0.72 g vs. 0.65 ± 0.69 g, p 0.047). CONCLUSIONS: Automatic optimization increased CRTd responders rate, and reduced hospitalizations for HF worsening. Intriguingly, automatic CRTd and highest baseline values of SonR could be predictive of CRTd responders. Notably, there was a significant difference in SonR values for CRTd responders vs. non responders, and about hospitalizations for HF worsening and cardiac deaths. Clinical trial ClinicalTrials.gov Identifier NCT04547244.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Diabetes Mellitus Tipo 2 , Ecocardiografia Doppler , Insuficiência Cardíaca/terapia , Tecnologia de Sensoriamento Remoto , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Tomada de Decisão Clínica , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Arrhythm ; 36(2): 353-362, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32256887

RESUMO

BACKGROUND: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D). METHODS: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE). RESULTS: In a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV, P < .01). The adjusted HR for 24 h AHRE in patients with atrial sensing >1.5 mV vs those with values ≤1.5 mV was 0.52 (95% CI: 0.33-0.83), P = .006. CONCLUSIONS: Although lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.

14.
J Clin Med ; 9(2)2020 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-32079238

RESUMO

OBJECTIVES: To evaluate atrial fibrillation (AF) recurrence and Sarcoplasmic Endoplasmic Reticulum Calcium ATPase (SERCA) levels in patients treated by epicardial thoracoscopic ablation for persistent AF. BACKGROUND: Reduced levels of SERCA have been reported in the peripheral blood cells of patients with AF. We hypothesize that SERCA levels can predict the response to epicardial ablation. METHODS: We designed a prospective, multicenter, observational study to recruit, from October 2014 to June 2016, patients with persistent AF receiving an epicardial thoracoscopic pulmonary vein isolation. RESULTS: We enrolled 27 patients. Responders (n = 15) did not present AF recurrence after epicardial ablation at one-year follow-up; these patients displayed a marked remodeling of the left atrium, with a significant reduction of inflammatory cytokines, B type natriuretic peptide (BNP), and increased levels of SERCA compared to baseline and to nonresponders (p < 0.05). Furthermore, mean AF duration (Heart rate (HR) 1.235 (1.037-1.471), p < 0.05), Left atrium volume (LAV) (HR 1.755 (1.126-2.738), p < 0.05), BNP (HR 1.945 (1.895-1.999), p < 0.05), and SERCA (HR 1.763 (1.167-2.663), p < 0.05) were predictive of AF recurrence. CONCLUSIONS: Our data indicate for the first time that baseline values of SERCA in patients with persistent AF might be predictive of failure to epicardial ablative approach. Intriguingly, epicardial ablation was associated with increased levels of SERCA in responders. Therefore, SERCA might be an innovative therapeutic target to improve the response to epicardial ablative treatments.

15.
J Cardiovasc Med (Hagerstown) ; 20(10): 676-681, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31343450

RESUMO

AIMS: The high rate of implantable cardioverter defibrillator (ICD) lead failures related to the Sprint Fidelis' and Riata's design have raised serious concerns about the reliability of ICD leads. The St. Jude Medical Durata family of leads replaced the preceding Riata line following increased rates of lead failure (1.17% per year). The aim of our study was to evaluate the long-term performance of the Durata lead. METHODS: Eight hundred and eighteen Durata ICD leads were implanted in 11 Italian centers. The incidence of lead failure, defined as a sudden rise in long-term pacing or defibrillation impedance and/or a sudden change in R-wave amplitude and capture thresholds, was assessed. The incidences of lead dislodgment and lead perforation were also evaluated. RESULTS: During a median follow-up of 1353 days (3.7 years; 25-75th interquartile range 806-1887 days) lead failure occurred in 16/818 leads (0.54%/year). The overall survival, free of lead failure, was 98.9% at 3 years, 98.2% at 4 years and 97.5% at 5 years. Lead dislodgment occurred in 12/818 leads with an incidence of 0.4%/year. No cases of cardiac perforation were reported. No major adverse events were reported except for two cases of inappropriate shocks as a consequence of failure or dislodgment. CONCLUSION: Our study suggests that the Durata lead does not engender a higher risk of failure. Overall survival, free from lead failure, was found to be higher than previously reported for the Riata lead.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardiopatias/terapia , Falha de Prótese , Idoso , Cardioversão Elétrica/efeitos adversos , Feminino , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo
16.
Clin Cardiol ; 42(9): 820-828, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31282000

RESUMO

BACKGROUND: The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor. HYPOTHESIS: The presence of an association between RR and the incidence of AHREs. METHODS: Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time-dependent proportional-hazard models, averaging over 30-day periods and adjusting for main baseline variables. RESULTS: After a median follow-up of 23.9 (12.2-36.0) months, 507 (60.6%) patients experienced at least one 15-minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (<68 bpm). Higher mean heart rates increased AHRE risk (HR:1.02, P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence. CONCLUSIONS: RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.

17.
J Cardiovasc Electrophysiol ; 30(9): 1626-1635, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31165517

RESUMO

INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardiomiopatias/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Tecnologia de Sensoriamento Remoto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Causas de Morte , Bases de Dados Factuais , Morte Súbita Cardíaca/epidemiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Falha de Prótese , Fatores de Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
18.
Diabetes Res Clin Pract ; 151: 152-162, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31004672

RESUMO

STUDY HYPOTHESIS: Cardiac autonomic dysfunction might lead to higher vaso vagal syncope (VVS) recurrence rate in type 2 diabetes mellitus (T2DM) patients vs. non diabetics patients. BACKGROUND: VVS recurrence might be due to alterations of autonomic system function, as assessed by heart rate variability (HRV). To date, in this study we investigated the correlation between HRV alterations and VVS recurrence at 12 months of follow up in T2DM vs. non T2DM patients. MATERIALS AND METHODS: In a prospective multicenter study we studied a propensity score matching (PSM) analysis of 121 T2DM vs. 121 non T2DM patients affected by VVS. RESULTS: T2DM vs. non T2DM patients had at baseline a higher rate of HRV dysfunction, and this was linked to higher rate of VVS recurrence at 12 months of follow up (p < 0.05). Blood pressure alterations and lower LF/HF ratio were linked to higher rate of all cause syncope recurrence, and of vasodepressor, cardio inhibitory, and mixed syncope recurrence (p < 0.05). Anti hypertensive drug therapies increased the number of vasodepressor and mixed syncope events (p < 0.05); alterations of heart rate increased syncope recurrence and mixed syncope recurrence events (p < 0.05). Finally, T2DM was linked to higher rate of VVS recurrence, and specifically of vasodepressor and mixed VVS recurrence (p < 0.05). CONCLUSIONS: T2DM patients have alterations of the autonomic nervous system, as result of cardiac autonomic neuropathy. However, T2DM diagnosis and autonomic dysfunction assessed by HRV alterations predicted VVS recurrence.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Cardiopatias/complicações , Síncope Vasovagal/etiologia , Teste da Mesa Inclinada/métodos , Diabetes Mellitus Tipo 2/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Síncope Vasovagal/patologia
19.
Cardiovasc Diabetol ; 17(1): 137, 2018 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-30348145

RESUMO

OBJECTIVES: To evaluate clinical outcomes in patients with diabetes, treated by cardiac resynchronization therapy with a defibrillator (CRT-d), and glucagon-like peptide 1 receptor agonists (GLP-1 RA) in addition to conventional hypoglycemic therapy vs. CRTd patients under conventional hypoglycemic drugs. BACKGROUND: Patients with diabetes treated by CRTd experienced an amelioration of functional New York Association Heart class, reduction of hospital admissions, and mortality, in a percentage about 60%. However, about 40% of CRTd patients with diabetes experience a worse prognosis. MATERIALS AND METHODS: We investigated the 12-months prognosis of CRTd patients with diabetes, previously treated with hypoglycemic drugs therapy (n 271) vs. a matched cohort of CRTd patients with diabetes treated with GLP-1 RA in addition to conventional hypoglycemic therapy (n 288). RESULTS: At follow up CRTd patients with diabetes treated by GLP-1 RA therapy vs. CRTd patients with diabetes that did not receive GLP-1 RA therapy, experienced a significant reduction of NYHA class (p value < 0.05), associated to higher values of 6 min walking test (p value < 0.05), and higher rate of CRTd responders (p value < 0.05). GLP-1 RA patients vs. controls at follow up end experienced lower AF events (p value < 0.05), lower VT events (p value < 0.05), lower rate of hospitalization for heart failure worsening (p value < 0.05), and higher rate of CRTd responders (p value < 0.05). To date, GLP-1 RA therapy may predict a reduction of AF events (HR 0.603, CI [0.411-0.884]), VT events (HR 0.964, CI [0.963-0.992]), and hospitalization for heart failure worsening (HR 0.119, CI [0.028-0.508]), and a higher CRT responders rate (HR 3.707, CI [1.226-14.570]). CONCLUSIONS: GLP-1 RA drugs in addition to conventional hypoglycemic therapy may significantly reduce systemic inflammation and circulating BNP levels in CRTd patients with diabetes, leading to a significant improvement of LVEF and of the 6 min walking test, and to a reduction of the arrhythmic burden. Consequently, GLP-1 RA drugs in addition to conventional hypoglycemic therapy may reduce hospital admissions for heart failure worsening, by increasing CRTd responders rate. Trial registration NCT03282136. Registered 9 December 2017 "retrospectively registered".


Assuntos
Arritmias Cardíacas/terapia , Glicemia/efeitos dos fármacos , Terapia de Ressincronização Cardíaca , Diabetes Mellitus Tipo 2/tratamento farmacológico , Cardioversão Elétrica , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Insuficiência Cardíaca/terapia , Hipoglicemiantes/uso terapêutico , Incretinas/uso terapêutico , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Biomarcadores/sangue , Glicemia/metabolismo , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/mortalidade , Progressão da Doença , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Feminino , Receptor do Peptídeo Semelhante ao Glucagon 1/metabolismo , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipoglicemiantes/efeitos adversos , Incretinas/efeitos adversos , Itália , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/efeitos dos fármacos
20.
J Arrhythm ; 34(4): 402-409, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30167011

RESUMO

BACKGROUND: Cavotricuspid isthmus (CTI) radiofrequency (RF) catheter ablation is the standard treatment for patients suffering from CTI-dependent atrial flutter (AFL). The aim of this study was to compare the use in clinical practice of 8-mm gold-tip catheter (8mmRFC) and open-irrigated gold-tip catheter (irrRFC) for RF typical AFL ablation. METHODS: Patients with typical AFL were treated with 8mmRFC or irrRFC catheters according to investigator preferences. The primary endpoint was the cumulative radiofrequency time (CRFT). Fluoroscopy time, acute and 6-month success rates were secondary endpoints. RESULTS: After excluding 3 patients with left AFL, 157 of the enrolled patients (median age 71.8 [interquartile range, 64.1-76.2], 76% men, 91% in NYHA class ≤II, 65% with no structural heart disease) were analyzed: 74 (47%) subjects were treated with the 8mmRFC and 83 (53%) with the irrRFC. The median CRFT was 3 [2-6] minutes in the 8mmRFC group and 5 [3-7] minutes in the irrRFC group (P = .183). There were no significant differences in ablation success rates, intraprocedural CTI reconnections, audible steam pops, and procedural times. In the 8mmRFC group, a significantly lower fluoroscopy time was observed as compared to the irrRFC group (8 [5-12] vs 15 [10-20] minutes, P < .001). During the follow-up period, AFL recurrences were documented in 3 patients in the 8mmRFC group and 2 in the irrRFC group (P = .655). CONCLUSIONS: The 8mmRFC and the irrRFC performed similarly in routine practice for CTI ablation in terms of cumulative RF time, acute and 6-month success rates. Fluoroscopy time was significantly lower in the 8mmRFC group.